smartLink HW-DP provides PLC independent access to PROFIBUS DP Networks. It enables Plant Asset Management for field devices using standard industry tools and allows using HART IP as a standardized format. smartLink HW-DP is a compact tool that can be integrated without interfering with the operation of existing installations. Thus, it enables Industry 4.0 connectivity for new and existing PROFIBUS DP networks.
smartLink HW-DP | ||
Hardware | Processor | Intel Cyclone V SoC with dual-core ARM Cortex-A9 |
Status LEDs (Gateway) | PWR, RUN, ERR, BUS | |
Real-Time Clock | Real-Time clock with buffering, setting the time via browser or by NTP server (buffer time depends on conditions such as ambient temperature and duration of use) | |
Interfaces and Connectors | Ethernet | IEEE802.3 10BASE-T/100BASE-TX/1000BASE-T |
PROFIBUS DP-V0 / V1 | 1 Segment with RS485 Physical Layer, Connector: 9-pin Sub-D socket | |
Physical Properties | Dimensions (H x W x D) | 120 mm x 28 mm x 110 mm |
Weight | Approx. 430g | |
Power Supply | 18 VDC ... 32 VDC; SELV/PELV power supply mandatory Typical input current: 200 mA, maximum input current: 1 A (allowing for in-rush current at switch-on) | |
Typical Power Loss | 5 W | |
Operating Temperature | -40 °C ... +65 °C (see detailed mounting description in user manual) | |
Storage Temperature | -40 °C ... +85 °C | |
Relative Humidity | 10 % ... 95 %, non-condensing | |
Cooling | Convection, no fan | |
Mounting | DIN rail 35 mm | |
Protection Class | IP20 | |
Conformity / Standards | CE | Electromagnetic compatibility (EMC) and Restriction of Hazardous Substances (RoHS) EN 61000-6-2 Generic standards - Immunity standard for industrial environments EN 61000-6-4 Generic standards - Emission standard for industrial environments EN 55032 Electromagnetic compatibility of multimedia equipment - Emission Requirements Class A EN 55011 Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics – Limits and methods of measurement Class A EN IEC 63000:2018 RoHS, Assessment to the restriction of hazardous substances |
FCC | FCC 47 CFR Part 15B Section 15.109 (Class A) | |
VCCI | VCCI Voluntary Control Council for Interferences by Information Technology Equipment, April 2015 |
Scope of Delivery | |
Hardware | smartLink HW-DP |
Documentation | On Website |
Order Numbers | |
GEA-YN-026000 | smartLink HW-DP, Access to PROFIBUS networks via Ethernet. Supports 1 PROFIBUS DP segment (RS485). Supports Emerson AMS Suite V14.1.1 and higher. |
LRA-NN-027004 | smartplus DP, Licensing access to one field device for smartLink/smartGate |
Additional Products and Services | |
LRL-DY-134501 | dataFEED OPC Suite, Version 4.01 and higher, including all supported PLC protocols, support for OPC UA, access for any number of dataFEED OPC Tunnel Clients, for simultaneous access to a total of up to 100 OPC UA Servers, OPC Servers and OPC Tunnel Servers, and many more Functionalities such as Database and File Access, Data Exchange, Optimizer, Concentrator and Bridge |
LRL-DY-14000 | dataFEED Secure Integration Server, Version 1.01, single user license for up to 10 OPC UA connections, including care and support contract for 1 year |
Integrate smartLink HW-DP with FieldCare to access HART field devices
In this tutorial, learn how to integrate and use the smartLink Hardware-DP solution into FieldCare Asset Manager tool from Endress & Hauser to retrieve HART information of field devices connected to HART compatible PROFIBUS DP Remote I/Os.
Integrate and use the Softing smartLink Hardware DP solution in AMS Device Manager
In this tutorial, you will see how to integrate and use the smartLink HW-DP solution into AMS Device manager and access PROFIBUS DP or HART information of field devices connected to HART compatible PROFIBUS DP Remote I/Os.