PROFINET to PROFIBUS DP/PA Master Gateway

Access to PROFIBUS DP/PA devices through virtual mapping as modular PROFINET device

  • pnGate PB re-uses power conditioners in technology upgrade projects
  • No PROFIBUS DP Intermediate Segment required
  • Prepared for Integration in Standard Engineering and Plant Asset Management Tools

Key Component for Transition to State-of-the-Art Technology

  • Simple replacement of installed PROFIBUS DP/PA segment coupler
  • Re-use of existing PROFIBUS segments without requiring modification
  • Support of PROFINET redundancy for increased reliability

Direct Connectivity to PROFIBUS Segments

  • Single access point to PROFIBUS DP and PROFIBUS PA segments from PROFINET networks
  • Acting as PROFINET Device, PROFIBUS PA and PROFIBUS DP Master
  • Support of one PROFIBUS DP segment and up to two PROFIBUS PA segments

Configuration, Parameterization and Plant Asset Management Using Standard Industry Tools

  • Supports major PROFINET engineering tools such as TIA Portal, Step7 and PC WORXS
  • Included CommDTM allowing use in FDT/DTM frame applications
  • EDD-based device parametrization using Siemens Simatic PDM
Technical Details
HardwareProcessor
Status LEDs (Gateway)

Status LEDs (Fieldbus)
Altera Cyclone V SoC with dual-core ARM Cortex-A9
PWR (power supply), RUN (operation), ERR (error), CFG (configuration and update)
SF (system fault), BF (bus fault)
Interfaces and ConnectorsEthernet





PROFIBUS PA



PROFIBUS DP-V0 / V1
2 * IEEE 802.3 100BASE-TX / 10BASE-T, embedded PROFINET switch for daisy chain topology
Connectors: RJ45
Protocol: PROFINET RT / IRT, Support of PROFINET redundancy protocols
RESTful API interface for device configuration
2 * PROFIBUS PA (MBP) segments,
Bus-powered Medium Attachment Unit (MAU): Fieldbus voltage range: 9 VDC ... 32 VDC,
current consumption 10 mA,
Connectors: 3-position screw connection, galvanically isolated
1 Segment with RS485 Physical Layer, Connector: 9-pin Sub-D socket
Physical PropertiesDimensions (H x W x D)
Weight
Power Supply



Operating / Storage Temperature
Relative Humidity
Cooling
Coating
Mounting
Protection Class
100 mm x 35 mm x 115 mm
Approx. 0.25 kg
18 VDC ... 32 VDC; SELV/PELV power supply mandatory
Typical input current: 200 mA, maximum input current: 1 A (allowing for in-rush current at switch-on)
No power supply to PROFIBUS PA segments through pnGate PB
-40 °C ... +70 °C / -40 °C ... +85 °C
(see detailed mounting description in user manual)
10 % ... 95 %, non-condensing
Convection, no fan
Conformal coating based on ANSI / ISA-S71.04 G3
DIN rail 35 mm
IP20
Scope of Delivery
HardwarepnGate PB Gateway
SoftwareFDT CommDTM, PACTware, Drivers and Tools
DocumentationOn CD-ROM
Order Numbers
GCA-AN-024608pnGate PB, PROFINET to PROFIBUS Gateway. Supports up to 2 PROFIBUS PA segments (up to 32 PA devices, MBP physical layer) and 1 PROFIBUS DP segment (RS485).
Additional Products and Services
GCA-AL-024602pnGate PA, PROFINET to PROFIBUS-PA Gateway. Supports up to 2 PROFIBUS PA segments (up to 32 PROFIBUS PA devices).
GCA-AL-024604pnGate PA, PROFINET to PROFIBUS-PA Gateway. Supports up to 4 PROFIBUS PA segments (up to 64 PROFIBUS PA devices).
GCA-AL-024605pnGate PA (for STAHL carrier), PROFINET to PROFIBUS-PA Gateway. Supports up to 4 PROFIBUS PA segments (up to 64 PROFIBUS PA devices). For reversed mounting position on STAHL backplane
GCA-EL-024802mbGate PA, Modbus/TCP to PROFIBUS-PA Gateway. Supports up to 2 PROFIBUS PA segments (up to 32 PROFIBUS PA devices).
GCA-EL-024804mbGate PA, Modbus/TCP to PROFIBUS-PA Gateway. Supports up to 4 PROFIBUS PA segments (up to 64 PROFIBUS PA devices).

x

Softing Industrial

Headquarter

+49 89 456 56-340


Callback Service

USA, Canada and Mexico

+1 865 251-5252


Callback Service


«

We use cookies to ensure the best experience on our website. Your cookies can be disabled at any point. By proceeding without changing your settings, you agree with us. More details can be found in your privacy policy.