PROFIBUS Tester 4 (BC-600-PB)
Quick and Easy Testing of Bus Physics and Bus Communication
Combines all in one device:
- Signal Tester
- Protocol Analyzer
- Storage Oscilloscope
Use Cases:
- Troubleshooting
- Preventive Maintenance
- Setup and Commissioning
- Documentation
- Acceptance Testing
- Optimization
- Laboratory Tests
Advantages:
- Time saving because it is easy to use and results are self-explanatory
- Cost saving, no expert knowledge necessary
Functions:
- Full bus testing without a Notebook and without operative PLC possible
- Bus-check possible during running operation
- Combines the diagnostic functions of previously separate tools in one device
- With a single mouse click (PC mode) or a single push of a button (stand-alone mode) a full examination of a PROFIBUS network is initiated
- The PC software provides many additional features for executing, analyzing, and managing bus tests.
- A status bar continually shows the current bus state
- Choice between quick test or user-controlled test
- The Topology Scan feature determines the overall cable length and the cable length between slaves
- Detailed test report
- The Long-Term Trend view is used for detecting sporadic faults
- In the oscilloscope and frame analyzer views, experts can perform in-depth detailed analysis
- For bus and device tests without operative PLC, only the baud rate needs to be specified – no configuration or parameterization is required.
| Power Supply | Via External AC Adapter 100 V .. 240 VAC 50/60 Hz (Galvanically Isolated) or Direct Connection to 24 VDC ±20%, Approx. 0.5 A (Without Galvanic Isolation) |
| RS485 (DP) | PROFIBUS D-Sub Connector, 9 Pins, Power Supply for External Bus Termination Protocol and Frame Analysis: PROFIBUS DP and DPV1, Automatic Baud Rate Detection 9.6 Kbit/s .. 12 Mbit/s Signal Analysis: PROFIBUS DP, DPV1, FMS and MPI; Signal Qality Index 0 .. 5000 Determined from Signal Waveform as well as Signal/Noise Ratio and Rise Time; Signal Sampling with 8/16 Samples per Bit Oscillogram display: Test Range: ±5V at 10mV Resolution (Differential), 0V...15V at 15mV Resolution (A or B to DGND); Sampling Rate: Up to 384MSamples/s; Sampled Points: 2,400 (Signal Details), 8,192 (Oscillogram Analysis) Topology scan: Active, Maximum Distance 230 m, Accuracy ±2 m |
| USB | V 2.0, High Speed 480 Mbit/s, Galvanically Isolated |
| Trigger | OUT: approx. 5 V, Active Low, Connection to Storage Oscilloscope |
| Internal Memory Capacity | 10 Memory Locations for Quick Tests, 1 Trend Log, for 41 Days Maximum |
| Dimensions | HxWxD: 35mm x 170mm x 110mm |
| Weight | Test Tool, No Cable: Approximately 0.45kg; Complete Carrying Case: Approximately 3.9kg |
| Ambient conditions |
|
| Conformity | CE, FCC, VCCI |
| Operation | Via Four-Line Display and Four Function Keys or via PC/Notebook. Display Localization: DE,EN,FR,IT,PL,ES (without National Language Specific Characters) |
| PC Operating Software | PROFIBUS Diagnostic Suite, see Separate Manual |
Downloads
- PROFIBUS Diagnostics BC-600-PB Data Sheet
- PROFIBUS Diagnostics Tester 4 "Deckel Maho" Success Story
- PROFIBUS Diagnostics BC-600-PB Manual
- PROFIBUS Diagnostics Suite V2.11 incl. FW Updates, Full Version
- PROFIBUS Diagnostics Suite V2.11 incl. FW Updates, Update only
- PROFIBUS Diagnostics Suite Manual
| BC-600-PB | PROFIBUS Tester 4, “All-In-One” Test Tool for PROFIBUS DP Bus Physics and Communication, Carrying Case, Wide-Range Power Supply with European and U.S. Power Cables, Connection Cable for 24VDC Direct Power Supply, “Standard” D-Sub PROFIBUS Adapter Cable, USB Cable, Terminal Block for Trigger Input/Output, User Manual, PB-DIAG-SUITE PC Software on CD-ROM With Getting Started Manual |
ADDITIONAL PRODUCTS AND SERVICES
| BC-600-PB-CB-DSUB1 | RS485 D-Sub Adapter Cable for Testing of Live PROFIBUS Segments with Reduced Influence on their Operation |
BC-600-PB-CB-M12 | D-Sub to M12 Adapter Set with T-Piece and M12 Bus Termination for PROFIBUS DP |
| BC-MOST-PB | External Power Supply Kit, including 24 VDC/1.5 Ah AC Adapter, 230 VAC Battery Charger and Carrying Case |
| PB-LSZ-CHB3 | Digital Fieldbus Leakage Current Clamp for Locating EMC Problems, 40 ..1000 Hz, MIN/MAX, Data Hold, Measuring Cables, supplied in a Handy Case (fits in Empty Compartment of Carrying Case) |
| BC-PBMB-PB-S | D-Sub Service Interface with Active Bus Termination and 90° Angled Connector for PROFIBUS DP |
| BC-M12DP-PB | M12 Service Interface for PROFIBUS DP, Comprising M12 T-Piece, End Cap and M12 Connection Cable (1 m) |
| TRA-PB-TECH | PROFIBUS Technology Training, 2-day |
| TRA-PB-TS | PROFIBUS Troubleshooting Training, 3-day |
Functionality of the Test Tools

Technical Data
| Operating systems | Windows XP, VISTA (32 Bit) and Windows 7 (32 + 64 Bit) |
| PC hardware* | RAM: ≥ 500 MB for Windows XP |
Screen resolution ≥ 1024x768 pixels (XGA) | |
USB interface 2.0 | |
| For recording at baud rates up to 1.5 Mbit/s: Processor ≥ 1 GHz | |
For recording at baud rates over 1.5 Mbit/s: Processor ≥ 2 GHz | |
| * The above minimum requirements are only general guidelines. Requirements may be higher depending on the PC/notebook used. |
Order Code
PB-DIAG-SUITE | PROFIBUS Diagnostics Suite, PC software on CD-ROM for BC- 4x0-PB, BC-502-PB, BC-600-PB and PB-T3, including Getting Started manual |
Additional Products and Services
| TRA-PB-TECH | PROFIBUS Technology Training, 2-day |
TRA-PB-TS | PROFIBUS Troubleshooting Training, 3-day |
Fieldbus Shield Digital Leakage Current Clamp - Locating EMC Problems | ||
| Measures leakage currents, e.g. leakage and fault currents, and current pick-up of instruments without breaking the circuit. Measurements according to DIN VDE 0701/0702 and the German BetrSichV (BGV A3, VBG 4). |
| ![]() |
Functionality | Included in Package | |
| Digital leakage current clamp, 2 batteries 1.5 V IEC LR6, carrying case, measuring cables (1 x red, 1 x black) and user manual. Order Number:PB-LSZ-CHB3 | |
Interface for Providing an Access Point to Test PROFIBUS Networks if the D-sub Connectors have no Service Socket or if the Devices are Connected via Terminal Block | ||
| Provides an access point for testing PROFIBUS networks if the D-sub connectors have no service socket or if the stations are connected via terminal block. |
| ![]() |
ApplicationThe service interface is top hat rail mounted. An external 24 VDC power source is required for power supply to the terminating resistor in the PROFIBUS connector included in the package. The service interface can thus be used as an active bus termination at the beginning or end of the bus. If the PLC allows dropping and adding bus stations on the live bus, the service interface offers the possibility to exchange the first and last bus stations without causing problems on the bus. Application example:
| Included in PackagePBMB adapter and 90° angled PROFIBUS connector with switchable terminating resistor, strain relief and screw terminal technology.Order Number:BC-PBMB-PB-S | |
Interface for Providing an Access Point to Test PROFIBUS Networks With M12 Connectors | ||
| Provides an access point for testing PROFIBUS networks with M12 connectors. |
| ![]() |
ApplicationThe service interface is inserted between two bus stations. When not in use, the service output of the T piece is closed with an end cap. At baud rates of 1.5 Mbit/s or higher, use the supplied cable to ensure that the required minimum distance between bus stations is maintained. Application example: | DownloadsIncluded in PackageT piece (protection class IP68) with end cap and a 1 m DP cable fitted with a male/female M12 connector on each end. Order Number:BC-M12DP-PB | |